Determining the resolution of an image used to be easy. In flat panel displays you counted the number of full-color pixels composed of RGB sub-pixels. In projectors, the count of the imager elements determined resolution.

Visual Display Resolution – a New Metric based Contrast Modulation and Structural Similarity

Chris Chinnock | Insight Media

Determining the resolution of an image used to be easy.  In flat panel displays you counted the number of full-color pixels composed of RGB sub-pixels.  In projectors, the count of the imager elements determined resolution.  

Well times have changed.  In flat panels, architectures are now common that use sub-pixel rendering algorithms to display color pixels from red, green, blue and white sub-pixel elements.  In the projection world, image shifting optics now allow the rapid display of two slightly displaced but complementary images that together increase the perceived resolution beyond that one would think possible based on the imagers in the projector.

These techniques have mainly been developed as cost saving scheme but they can also sacrifice high spatial frequencies resulting in a visual loss of fidelity on letters and detailed images.  Figure 1 shows a conventional RGB stripe architecture on the left while on the right is an RGB architecture where the sub-pixels are not aligned vertically.  This architecture may not have much impact on video content compared to the RGB stripe version, but it can impact fidelity on static images.

Figure 1: Sub-pixel rendering can reduce image fidelity (display B)

New methods to measure resolution are needed.  Recently, Samsung proposed a method that builds on existing contrast modulation methods and leverages the concepts of Structural SIMilarity (SSIM) to evaluate the resolution of flat panel displays.  SSIM is a common metric used in the video and movie encoding industries to test and compare different compression schemes.  As far as we know, this is the first time it have been applied to try to determine the resolution of a display.

 

What is Contrast Modulation?

To understand why elements of SSIM have value, we first need a little background to understand how the measurement of resolution has evolved to date.  One of the key measurement techniques is contrast modulation.  The use of contrast modulation (Michelson contrast) to determine resolution has been used for CRT displays for a long time.  To measure contrast modulation, a series of vertical or horizontal lines are written to the display.  Contrast modulation, Cm, is calculated as follows:

Where Lw is the peak luminance of the white (or colored) peak and Lk is the luminance of the trough between the peaks.  

If the spacing between the lines is relatively large, a clear separation between the bright and dark lines will be evident and the contrast modulation will approach unity.  As the separation between the lines decreases, typically to single-pixel-wide line pairs, the display may struggle to show a clean separation of the bright and dark lines, so Cm will fall.  If the contrast modulation is too low, it is hard to see any separation – i.e. to distinguish two separate pixels.  

In the CRT days, a Cm value of 0.5 was generally considered to be the threshold for the determination of the resolution of the CRT display.  This concept has been applied to flat panel displays, although there is some disagreement among metrology professionals as to what value of Cm should be used to determine resolution.  Resolution in the horizontal or vertical direction is determined by counting the distinguishable peaks (i.e. above a certain Cm threshold).

Contrast modulation works well in conventional RGB flat panel architectures.  That is, one color pixel that is composed of red, green and blue sub-pixels that are arranged horizontally in neat and aligned rows and columns.  Resolution in these displays can simply measured by counting the RGB sub-pixels horizontally and vertically.  But applying the contrast modulation scheme works quite well too.

Read the full white paper here.
 
 
 
The content & opinions in this article are the author’s and do not necessarily represent the views of HomeToys

Comments (0)

This post does not have any comments. Be the first to leave a comment below.


Post A Comment

You must be logged in before you can post a comment. Login now.

Featured Product

PureLink - HCE III TX/RX: 4K HDR over HDBaseT Extension System w/ Control and Bi-Directional PoE

PureLink - HCE III TX/RX: 4K HDR over HDBaseT Extension System w/ Control and Bi-Directional PoE

The HCE III Tx/Rx HDBaseT™ extension system offers full HDMI 2.0 compliance supporting HDR (High Dynamic Range) and 4K@60Hz with 4:4:4 chroma sampling. Featuring PureLink's proprietary Prcis codec, a light compression technology, the HCE III can transport Ultra HD/4K, multi-channel audio, and High Dynamic Range (10 bits support) content over a single CATx cable. The HCE III provides HDMI extension up to 130 feet (40 meters) at Ultra HD/4K and up to 230 ft. (70 meters) at 1080p over category cable with embedded multi-channel audio, CEC pass-through, bi-directional RS-232 and IR control, and PoE - all with zero loss and zero noise. The HCE III Tx/Rx also supports Dolby TrueHD, Dolby Digital Plus and DTS-HD Master Audio plus LCPM (up to 192 kHz). Additionally, the low profile "slim box" enclosure design make the HCE III ideal for limited space installation environments, such as behind flat panel displays and video walls.