For anyone new to the world of acoustics, there is a multitude of terms, coefficients and numbers that are thrown around. This flood of information can seem intimidating, especially to beginners.

Demystifying Acoustic Data: Part 3 – Perception of Volume

Contributed by | Acoustics First

For anyone new to the world of acoustics, there is a multitude of terms, coefficients and numbers that are thrown around.  This flood of information can seem intimidating, especially to beginners. In this series, acoustician Cameron Girard of Acoustics First® hopes to help you distinguish between what’s useful and what’s not.

Click Here to read Part 1 Absorption vs Isolation

Click Here to read Part 2 Test Mount Material

 

Part 3: Perception of Volume

Our ears are wonderful and intricate tools that many of us take for granted. It is very important to understand the idiosyncrasies of our hearing when considering the effect a certain acoustic treatment will make. For starters, let’s take a look at how our ears interpret volume.

 

Volume (Sound Intensity)

Sound levels (i.e. how loud something is) are typically expressed in decibels (dB). Human hearing ranges from 0dB (threshold of hearing) to 130dB (threshold of pain). The following chart displays common sound sources and their typical dB level.

 

Do two candles really burn twice as bright?

If one trombonist plays at 70dB, how much louder would it be if another trombonist started playing at 70dB? One might assume that the two trombonists combined would play at 140 dB, but this is not the case. Since decibels are logarithmic values, they cannot be combined by normal algebraic addition. When two sources at the same level play, 3dB should be added to the value to find the combined sound level. So in adding another trombonist, you would really only increase the level to 73dB, a much smaller jump than expected.

“Doubling” the amount of players will double the acoustic power, but what do we actually hear? The loudness perception table shown below displays how these decibel changes are actually perceived by the listener.

 

Loudness Perception Table

Change of Level Approx. Perceived Difference Volume Gain Factor Acoustic Power Gain Factor
+10dB “twice as loud” 2.000 10.000
+6dB “significantly louder” 1.516 4.000
+3dB “noticeably louder” 1.232 2.000
±0 “no change” 1.000 1.000
– 3dB “noticeably quieter” 0.812 0.500
– 6dB “significantly less loud/noisy” 0.660 0.250
– 10dB “half as loud” 0.500 0.100

*Chart Courtesy of David Eagan’s Architectural Acoustics (New York: McGraw-Hill, 1988),

As you can see, doubling the acoustic power (a change of 3dB) would be “noticeable” but not “significant”.  It would take a jump of 10dB to make something sound twice as loud. Keep this chart in mind when reviewing acoustic predictions, particularly those that that pertain to noise reduction/control and sound isolation.

 

The content & opinions in this article are the author’s and do not necessarily represent the views of HomeToys

Comments (0)

This post does not have any comments. Be the first to leave a comment below.


Post A Comment

You must be logged in before you can post a comment. Login now.

Featured Product

ELK Products -C1M1 Dual-Path Alarm Communicators with Remote Services

ELK Products -C1M1 Dual-Path Alarm Communicators with Remote Services

C1M1 offers a truly significant reduction in transmission time in comparison to other communicators that rely on dial capture or data bus decoding. This can result in quicker response time to emergency situations which could save lives and assets. By providing both IP and cellular pathways, C1M1 provides the reliability installers are looking for in an alarm communicator. C1M1 eliminates port forwarding and extra fees for remote access. Installers can remotely upload/download programming changes to M1 controls over IP or cellular using ElkRP2. Consumers can control the M1 remotely via the free ElkLink mobile app and web portal, as well as eKeypad and M1 Touch Pro apps. Other IP-based software and interface partners can connect to the M1 control over the local network through C1M1. C1M1 also provides email/text notifications for arm, disarm, and alarm events. ELK-C1M14GSM supports GSM (AT&T/T-Mobile) networks and ELK-C1M1CDMA supports CDMA (Verizon) networks.